Abstract
In order to improve the weak optical performance of gold nanoparticles and realize the signal amplification of lateral flow chromatography test strips, individual gold nanoparticles (AuNPs) were aggregated into gold nanoparticle aggregates through functional groups around polyamidoamine (PAMAM) dendrimers. A signal-amplified aptamer-based lateral flow chromatography test strip was constructed for the rapid determination of ochratoxin A (OTA). Under optimal conditions, the visual detection limit of this test strip was 0.4 ng mL−1 and the semi-quantitative limit of detection (LOD) was 0.04 ng mL−1. Compared with other traditional aptamer lateral flow chromatography test strips, its sensitivity was improved about five times. The whole test could be completed within 15 min. The aptamer-based strip was applied to the detection of OTA in red wine; the average recoveries ranged from 93% to 105.8% with the relative standard deviation (RSD) varying from 3% to 8%, indicating that the test strip may be a potentially effective tool for the on-site detection of OTA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.