Abstract

Rheumatoid arthritis (RA) is a chronic disease, in which permanent joint deformation is largely preventable with the timely introduction of appropriate treatment strategies. However, there is no consensus for patients with RA to monitor their progress and communicate it to the rheumatologist till the condition progresses to remission. In response to this unmet need, we proposed the design of a self-measuring device based on bioelectrical impedance analysis (BIA) for regular monitoring of inflammation levels. Twenty joints of both hands were measured to monitor trends in inflammation levels. Three electrodes were used to measure two joints of each finger. A central electrode was used for two consecutive measurements. A suitable form factor for the device was proposed for the vertical placement of the hand. To ensure the stability of measurements, an air cushion was incorporated into the back of the hand, hand containers were designed on both sides, and a mobile application was designed. We conducted a convergence-assessment experiment with five air pressures to validate the consistency and convergence of bioimpedance measurements. A heuristic evaluation of the usability around the product and mobile application was conducted in parallel by six subject matter experts and validated the design. This study underscores the significance of considering patients' disease activity during intervals between hospital visits and introduces a novel approach to self-RA care.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call