Abstract

The diagram constructed for selection of sampling methods indicates that, for a systematic error, E ≤ 13%, grab sampling (GS) may be used to characterize effluents with variation coefficient of flow ≤ 120% and of contaminant concentrations ≤ 10%. For the whole studied range of variation coefficient of contaminant concentrations (2–82%), time-proportional compositing (TC) method may be applied with E ≤ 10% for effluents characterized by variation coefficients in flow < 90%. The more complicated flow-proportional compositing (FC) method is required only for effluents with larger variation coefficients or to produce more precise results. The diagram constructed for selection of sampling frequencies indicates that sequential sampling at intervals of approximately 60 min may be applied with E ≤ 10% for effluents characterized by variation coefficients ≤ 30%. Practical application of the diagrams, constructed using normal series, was checked against monitoring data from two pulp and paper mills in Vietnam. The two diagrams provided results on sampling methods and frequencies in good agreement with those obtained from actual monitoring data with percentages of agreement cases of 80 and 75%, respectively. The approach was applied in design of a monitoring program at the Bai Bang integrated pulp and paper mill in Vietnam.