Abstract

The dynamic behavior of a parabolic trough collector field with direct steam generation under varying solar conditions is analyzed using a transient simulation model. It is found that the peak water flow rates observed during transients may reach several times the steady-state design values. Taking into account these results, a method is developed for calculating the required separation efficiency of the water-steam separator between evaporating and superheating sections of the solar field. For a field with individual phase separators arranged in each collector row, the drainage system, used for transporting the separated water from the field to a central buffer tank, is dimensionally defined. It turns out that a buffer capacity of about 0.1m3 and a large-diameter drainage line have to be foreseen in order to cope with the high liquid loads under solar transients. The results are compared to a field layout with one central separation drum in terms of materials consumption and thermal inertia. It turns out that the originally intended effect of a reduced thermal inertia is not reached when transient conditions are taken care of in the design of the components.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.