Abstract

Atrazine (ATZ) is widely used in agriculture as a triazine herbicide, and its long-term use can cause serious environmental pollution. This paper independently designed a multi-electrode reactor, explored the output power and energy utilization efficiency of the dielectric barrier discharge reactor, and used the dielectric barrier discharge reactor to treat ATZ solution. The results showed that the degradation efficiency of ATZ was 96.39% at 30 min at an initial ATZ concentration of 14 mg/L, an input voltage of 34 kV, an input current of 1.38 mA, an aeration rate of 100 L/h, and a treatment water volume of 150 mL. The degradation of ATZ was significantly increased by the addition of persulfate (PS), Fe2+, and H2O2. After adding radical quenchers (EtOH, p-BQ, and FFA), the degradation efficiency of ATZ decreased, indicating that free radicals (•OH, •O2-, and 1O2) played a key role in the degradation process of ATZ.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.