Abstract

Design of a discretized hyperbolic paraboloid geometry beamforming array of capacitive micromachined ultrasonic transducers (CMUT) has been presented. The array can intrinsically provide a broadband constant beamwidth beamforming capability without any microelectronic signal processing. A mathematical model has been developed and verified to characterize the array response. A design methodology has been presented that enables determination of the array's physical dimensions and CMUT modeling in a straightforward manner. Developed methodology has been used to design two discretized hyperbolic paraboloid geometry beamforming CMUT arrays: one in the 2.3 MHz to 5.2 MHz frequency range and another in the 113 kHz to 167 kHz frequency range. CMUTs have been designed using a cross-verification method that involves lumped element modeling, 3-D electromechanical finite element analysis (FEA), and microfabrication simulation. The developed array has the potential to be used in real-time automotive collision-avoidance applications, medical diagnostic imaging and therapeutic applications, and industrial sensing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.