Abstract

In this paper, a photonic crystal waveguide platform on silicon-on-insulator substrate is proposed in order to realize a highly sensitive refractive index based biosensor. Following the design, the analysis of the sensor structure are made by using the three dimensional Finite Difference Time Domain method. The principle of sensing is based on the change in refractive index, which in turn changes the output spectrum of the waveguide. Results show that the sensitivity of the sensor depends mainly on the geometrical properties of the defect region of the photonic crystal structure. The phenomenon is verified for various samples having refractive index ranging from 1 (air) to 1.57 (Bovine serum albumin). Further, the structure is compared with few other conventional photonic crystal waveguide designs to analyze the sensing performance. The estimated value of sensitivity of the sensor is found to be 260 nm/RIU with a detection limit of 0.001 RIU. This high sensitivity can enhance the performance of low-concentration analytes detection.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call