Abstract

This paper reports a novel design of a microchined bolometer for thermal imaging applications. The thermal modeling and stress analysis of infrared radiation bolometer which is made of a thin film of aSi:H has been performed using FLUENT(6.1) and ANSYS (11) CFD programs respectively. This bolometer is realized in a multilevel electro thermal structure having a high fill factor. Using the multilevel structure, thermal isolation can be independently optimized without sacrificing the IR absorption area. The analysis showed that optimization of the arm dimensions can be done without failure of structure breakdown or buckling. The design shows that the thermal time constant is 12.95 ms, the responsivity is of 4.65×103 V/W, and the detcetivity is of 7.97×108 cm Hz1/2 w−1 which can be achieved in a 50μm×50μm michromachined structure

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.