Abstract

The increase in power demand, nonlinearity, complexity, varying structure, and other important causes has necessitated the implementation of artificial intelligent control methodologies for safe and acceptable operation of the electric power systems. Therefore, in this article, an improved two-degrees-of-freedom (2DOF-PID) control scheme is proposed for power/frequency control of a two-area interconnected electric power system. The parameters of the 2-DOF-PID control scheme are optimized using the Dragonfly Algorithm (DA) via a new integral-based weighted goal fitness function (IB-WGFF) (i.e., DF-2DOF-PID-IB-WGFF). The superiority of the suggested scheme is proved by comparing the results obtained using the proposed IB-WGFF with those obtained using the conventional controllers, and the 2DOF-PID controllers optimized using the DA and Genetic Algorithm (GA) via the frequently published performance criterion. To verify the stability, efficacy, and robustness of the proposed control scheme, a load disturbances and parameters perturbations with various percentages are implemented in the controlled system under the same controllers. Finally, verification results proved that the proposed 2DOF-PID optimized using DA via the IB-WGFF is more stable, efficient, and robust than the other controllers recently used in the literature.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call