Abstract

A non-corrosion, high strength, light weight material – carbon fiber reinforced polymer (CFRP) is introduced to replace steel as cable system in long-span suspension bridge for improving loading efficiency, reducing maintenance cost, enlarging the span of suspension bridge. Because of the transverse weakness of CFRP, traditional cable saddle is not suitable. The contact forces between main cable and cable saddle slot under final state are investigated with a simplified analytical method. According to the mechanical characteristics of CFRP and the formulas deduced, the design suggestion of cable saddle for CFRP main cable of long-span suspension bridge are proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.