Abstract

The design factors of fountain confined conical spouted beds have been assessed in order to determine their best combination for scaling up and enhancing fine particle retention. The results evidence that the length of the confiner and the height of the draft tube entrainment zone are the key design factors, causing the highest entrainment reduction. Thus, the optimum confiner length is within the range of 2-3 times the bed surface diameter and the desirable height of the entrainment zone is approximately 1-2 times the tube diameter. This study also concludes that the best system for attaining high stability with minimum elutriation is the one equipped with an open-sided draft tube with an aperture ratio of around 20%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.