Abstract

An arrangement for heating with solar energy by means of a heat exchanger and storage coupled to the two water heaters has been described ∗. In the present paper, the amount of the heat transferred from water to air in the shell-and-tube heat exchanger and the temperature of the outgoing air have been estimated by considering various parameters, viz. flow rate and temperature of incoming air, temperature of incoming and outgoing water, length and diameter of tubes, etc. Both natural and forced convection mode of heat transfer have been considered. Under boundary conditions of free convection, heat transfer would be rapid and efficient with a possible reduction in the pipe length. The maximum permissible limit of pressure drop per foot of each tube for pipes of different diameters at different Reynolds numbers has been given. As conditions of drying vary from material to material, the data presented will help in arriving at the final design of the shell-and-tube heat exchanger to be used in drying a particular material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.