The main design and test requirements for motor controllers in the 2200 V to 5000 V range as given in Underwriters' Laboratories Standard UL 347 are outlined. The ways in which these requirements are met in a typical starter are described. Design requirements are reviewed on guarding live parts, grounding, wiring space, isolating means, and interlocking. The extensive performance test program specified in the standard is described, including operating tests, short- time capability tests, temperature tests, dielectric tests, overload tests, and short-circuit interruption tests.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.