Abstract
This study addresses design aspects for the punching shear bolt retrofitting system for reinforced concrete flat slabs supported on columns. Shear bolts are an external type of reinforcement installed in existing slabs by first drilling small holes through the slab thickness, installing the bolts into them, and tightening the bolt nuts. Previous experimental research at the University of Waterloo showed the effectiveness of this system in increasing strength and ductility of existing slabs, with little changes in the slab’s appearance. The procedures for the design of the shear bolts and their installation in slabs are proposed in the paper. Recommendations are provided regarding the stem diameter, the head area and thickness, and the spacing and the layout of the bolts in a plane of a slab.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.