The paper presents an application of the Galerkin triangular mesh finite element method using linear approximation, in axisymmetrical and plane geometry, to the design of liquid metal annular induction pumps. The code was tested by comparison with: - analytical calculations in simple geometry cases (15 × 15 square mesh) - test results on pumps constructed. Each calculation is also checked by internal balance of powers. The finite element method is particularly suitable for this application where a practical analytical method is not sufficiently accurate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.