Abstract

Producing a stable and agile bionic eye for visual image acquisition in robotics is a challenging task. In this paper, we design a bionic eye with mirror-symmetric distribution and cross-connection of flexible ropes. This mechanism is based on oculomotor law and the physiological structure of the extraocular muscles (EOMs). Specifically, the basic structural parameters are determined by Listing’s law, and the unique connection of the flexible ropes can realize the functions of the recti and oblique muscles. Furthermore, to mimic the trochlea structure, a pulley mechanism is constructed to permit the free movement of the flexible ropes. Through simulation and physical experiments, it is demonstrated that the bionic eye mechanism can move with agility under the structural parameters. The experimental results indicate that the proposed bionic eye mechanism has a superior motion accuracy of 2.798 mm, which is 6.7% of the maximum motion distance, and the repeatable accuracy of the mechanism can up to 0.210 mm.