Abstract

In this paper, the problem of the Low Voltage (LV) and High Voltage (HV) power supply distribution of the MDT (Monitored Drift Tubes) detector is addressed. Due to the high number of channels (1168 for low voltage and twice for high voltage) involved and to the dimension of the apparatus, these power supply systems are very complicated. Both system are made of three different parts: a power generator, a system controller and an active distributor. The first two parts will be localized in the cavern close to the experimental area, so they are subjected to standard environmental conditions. The third part (the active distributor) will be placed in the experimental area on the platforms just outside the detector, where the environmental conditions are more severe, due to the presence of magnetic field (about 800 Gauss) and radiations. In the following we present the design specifications and tests for the power supply systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.