Abstract

A multi-frequency microwave radiometer has been built to study the microwave remote sensing of soil, snow and vegetation cover. Its accuracy and stability has been tested. This article described the performance of its design and the performance of its components. Two absolute calibration methods and a relative calibration method and the calibration results are introduced. The theoretical and practical accuracy of the measured brightness temperature is in the range of 0.3 K-1.0 K. It is proved to be reliable and helpful in relative microwave remote sensing researches.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.