Abstract
Since magnetic core of an inductor is easily saturated and then absorbs extra energy due to saturation, most of inductors are designed with an air core. The inductor requires so many wires to make large inductance and these expensive coils are one of the weak points of the dc reactor type fault current limiter (FCL). To solve this problem, reverse magnetization bias method is introduced. One kind of fault current limiter using dc biased saturated core has been studied in this paper. All exciting saturated cores are ac type. The proposed FCL is a dc reactor type where all the windings carry dc current. The B-H curve of a magnetic circuit shows that less inductance value can be achieved in saturated region and very high value in unsaturated region. The reactance window between the saturated and unsaturated region depends on magnetic material, core size and its biasing condition [1]. The complete mathematical analysis in different modes of operations of the proposed FCL is given. The simulation results are presented to validate its effectiveness.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.