Abstract

Capacitance measurement accuracy is affected by phase conformity between signal and reference. This work describes phase detection scheme which is necessary for phase synchronization in tomography application. Core processing for calculating phase and amplitude of the detected signal was built on FPGA (Field-Programmable Gate-Array) platform. Phase shift demodulation algorithm employs IP core provided by Xilinx FPGA. Direct digital synthesizer (DDS), multiplier, accumulator, and CORDIC (coordinate rotation digital computer) modules were used as excitation-reference signal generator, signal multiplication, accumulation, and conversion to polar coordinate in order to conduct trigonometric operation respectively. Hardware design was emulated on MATLAB-Xilinx System Generator to observe its performance. Phase detection range 0-114.58 o and mean absolute error 0.58 o have been achieved. Data processing rate solely at digital signal stage was approximately 100data/s suitable for 32-channel electrical capacitance volume tomography (ECVT) system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.