Abstract

Abstract This article compares two sensorless control algorithms for a permanent magnet synchronous machine (PMSM) based on the back-EMF sliding mode observer (SMO). Indirect SMO (I-SMO) treats the back-EMF voltages as a disturbance. Direct SMO (D-SMO) considers back-EMF voltages as state-space variables. The same phase-locked loop (PLL) is used for both observers for extraction of the rotor position and speed values from the observed back-EMF voltages. In a sensorless control, the observed speed is used as feedback for the PI controller, and the observed position is used in the Park transformations. Both observers have been implemented and tested with standard field-oriented control. Simulation results indicate rather comparable speed and position estimation precision for both, but the D-SMO indicates slightly higher precision in steady-state. Even more, a tuning procedure of the D-SMO is more straightforward when compared to the I-SMO. Thus, the D-SMO was further verified experimentally with the OP 5600 rapid prototyping device and with a 350 W PMSM drive. Experimental results of the D-SMO are included at the end of the paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.