Abstract
The radial X-ray camera, which is used to measure magnetohydrodynamic phenomenon and monitor edge localised mode events, is a key diagnostic system for physics studies in the international thermonuclear experimental reactor (ITER) tokamak. Considering the special requirements of physics measurements and spatial resolution, 144 detector channels are required. The board card of the pre-amplifier is designed to improve the integration, on which 16 signal channels have been integrated. In order to suppress the noise and improve the stability of the pre-amplifier, the target impedance analysis method is applied in the design of the power supply, the trans-impedance amplifier and a two-stage active low pass filter are applied in the design. Simulation with Cadence OrCAD and ANSYS SIwave has been adopted to optimize the characteristics of the pre-amplifier. A test of the pre-amplifier shows its good performance for ITER application. After optimization of the pre-amplifier, the band width is 270 kHz, the amplification is 107 V/A, and the noise attenuation is − 30 dB, the noise of the pre-amplifier is reduced to 10 mV (noise of the power supply is included).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.