Abstract

This article in view of existing BOP seal leakage point, low service life, large volume,high weight, height and installation of time-consuming to faults, the annular BOP and ram preventer, one-piece BOP design scheme is put forward, and seal the mouth of the well on the whole, 21 mpa pressure blowout limit design conditions for structural reliability analysis of one-piece BOP.The analysis results show that because the integrated BOP uses the integrated shell, does not need to use the flange connection, less leakage points, can greatly improve the traditional BOP short life, easy to leak and other shortcomings, and the maximum stress and maximum deformation displacement meet the design requirements.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have