The main aim of this work to design and select the optimal photovoltaic based energy system that can meet the rural area irrigation and domestic load demand. The selection of optimal energy system configuration is based on modeling, economic and reliability analysis. Soft optimization computing tool (MATLAB & HOMER Pro) and Markov reliability method are used to identify optimal energy system configuration. The results show that COE of PV/battery is ₹6.87, PV/diesel/battery is ₹14.29, PV/DG is ₹30.25, DG/battery is ₹34.71 and DG is ₹36.12. Energy capacity shortage is higher in PV/battery (8%) and approx. zero in PV/DG/battery system. Reduction of fuel cost from diesel only system to hybrid PV/DG/battery energy system is 42.46%. PV/DG/battery failure rate (0.01101), EENS (0.080) and LOLP (0.00000725) are minimum as compared to another configuration. The obtained results concludes that hybrid PV/DG/battery energy system is cost-effective, sustainable and reliable system for rural areas in India.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.