Abstract
Using the downhole annular flow measurement system to get real-time information of downhole annular flow is the core and foundation of downhole microflux control drilling technology. The research work of electromagnetic flowmeter in recent years creates a challenge to the design of downhole annular flow measurement. This paper proposes a design and optimization of annular flow electromagnetic measurement system for drilling engineering based on the finite element method. Firstly, the annular flow measuring and optimization principle are described. Secondly, a simulation model of an annular flow electromagnetic measurement system with two pairs of coil is built based on the fundamental equation of electromagnetic flowmeter by COMSOL. Thirdly, simulations of the structure of excitation system of the measurement system are carried out, and simulations of the size of the electrode’s radius are also carried out based on the optimized structure, and then all the simulation results are analyzed to evaluate the optimization effect based on the evaluation indexes. The simulation results show that optimized shapes of the excitation system and electrode size can yield a better performance in the annular flow measurement.
Highlights
In recent decades, oil and gas exploration is being carried out in some extremely harsh and challenging environmental conditions [1]
The design and optimization of the downhole annular flow electromagnetic measurement system with two pairs of electrodes cannot be investigated based on the traditional Faraday theory
This paper described the design and optimization of annular flow electromagnetic measurement system for drilling engineering
Summary
Oil and gas exploration is being carried out in some extremely harsh and challenging environmental conditions [1]. E = BDv, where E is the signal voltage in a conductor, v is the average flow velocity, B is the magnetic flux density, and D is the pipe diameter. The annular flow electromagnetic measurement system is difficult to yield a uniform magnetic field for an annular flow path, and the velocity profile of the annular flow cannot be considered axisymmetrically distributed under this special drilling environment. This affects the accuracy of the annular flow electromagnetic measurement system. The design and optimization of the downhole annular flow electromagnetic measurement system with two pairs of electrodes cannot be investigated based on the traditional Faraday theory
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have