Abstract

To investigate the microchannel liquid cooling system of 18650 cylindrical lithium battery packs, cooling systems with varying numbers of microchannels are developed and they are analyzed through numerical simulations using COMSOL software. The findings reveal that lower coolant inlet temperatures correspond to lower maximum temperatures during discharge, with temperatures decreasing closer to the inlet. When the coolant passes through a 3.6 mm diameter or at an inlet flow rate of 0.1 m s−1, an increase in Reynolds number results in a decrease in the highest temperature of the cells. However, this temperature reduction slows down when Re exceeds 400. The annular channel cooling structure demonstrates superior cooling effects and temperature uniformity. Optimization opportunities exist to reduce the number of inlets. The dual‐inlet and dual‐outlet cooling structure has been enhanced by adjusting the number of channels in the annular channel design. This modification has resulted in a maximum temperature reduction of 4.62 K and a temperature difference of less than 5 K compared to the initial reference group, demonstrating effective cooling performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.