Abstract

Precisely separating particles/cells with different sizes and physical properties has been an interest for point-of-care diagnostics and personalized treatment. Dielectrophoresis (DEP) is widely known as a powerful and non-invasive technique to separate particles and cells. This paper presents a comprehensive numerical investigation of particle/cell separation in circular microchannels using DEP. First, the geometrical parameters of the circular microchannel affecting DEP force are determined by performing an analytical solution. Then, by developing a solver in OpenFOAM, the effect of these parameters on particles deflection is investigated. According to the results, two different circular microchannels are presented to investigate the continuous separation of bio-particles (based on their physical properties) and polystyrene particles (based on their size). The results showed that a minimum voltage of 7, 9, and 12 V is required to achieve 100 % purity and separation efficiency for separating red blood cells from MDA-MB-231 cancer cells at the flow rate of 0.5, 1.0, and 1.5 µl/min, respectively. Also, the efficient separation of 5 and 10 µm polystyrene particles at the flow rate of 0.1 µl/min is possible only at the voltage of 9 V. The results of this numerical study can be useful for the fabrication of an optimal microdevice for the continuous DEP separation of particles and cells.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.