Abstract

To verify ships' compliance with ballast water regulations, samples may be collected and tested for viable organisms. This task is completed using a sample probe, which is placed in the ballast discharge pipe through a sample port (a flanged opening). To collect representative samples, the placement of the sample port and the size of the sample probe must be appropriate for the shipboard piping arrangement and ballast water flows. The placement of sample ports was evaluated on 72 ships to assess the current condition of ballast water sampling installations against available guidance. Few ships (15%) had sample ports fully aligned with International Organization for Standardization (ISO) standard 11711-1. While current configurations may present challenges in collecting representative samples, these installations likely occurred before the ISO standard was available. Future installations should be in accordance with the standard to facilitate representative sampling.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.