Abstract
A new approach for output feedback L1 adaptive control based on a proportional adaptation law is presented. The effectiveness of this design is assessed in simulation and validated through real-time testing on an airfoil pitch control wind tunnel experimental rig. Experimental evaluation of the robustness of the controllers, assessed by introducing various disturbances into the control signals, shows that the adaptive control has a better performance compared to PID control, particularly in scenarios with reduced control effectiveness and time-varying disturbances. The experimental results demonstrate the efficacy of the proposed method in practical applications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.