Abstract

The measurement of the total losses of electrical machines is of most interest to designers for verifying their calculations. We show the limitations of the conventional input-output procedure leading to loss figures. An alternative method is proposed. For this purpose, a calorimetric measurement facility was designed and implemented. This paper is intended to present the calibration procedure for this facility, as well as results of tests performed on a 10 hp (7.5 kW) induction motor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.