Abstract

In order to make a research on long pulse or even steady state operation with non-inductive drive in plasma discharge, a new feedback control scheme instead of the previous one has been designed and operated in HT-7 [HT-7 team presented by J. Li, et al., Plasma Phys. Control. Fusion 42 (2) (2000) 135–146] Tokamak experiment, 2004. Consumption of iron-core transformer magnetic flux (MFT) is feedback controlled for the first time by power of lower hybrid current drive (LHCD) P LH, when the Ohmic-heating circuit current can maintain the plasma current I P constant with another feedback control loop, which make MFT evolve at alternating-change state to avoid flux saturation. Plasma current I P can be maintained steadily up to 120 s in this operation mode at reduced plasma parameters ( I P ≈ 50–100 KA, average density n ¯ e = 0.4 – 0.5 × 10 19 m − 3 , P LH = 100–200 KW). Design and experimental results are presented in the paper, which including control model analysis, configurations of control system and MFT feedback control experiments in HT-7. The high voltage power supply (HVPS) of LHCD is the main controller that regulates the LHCD power into the plasma to control the MFT.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call