Abstract

Abstract The paper describes the practical way and security conditions of realizing the demolition of an industrial chimney located in an oil refinery platform, having in the immediate vicinity sensitive equipment and constructions. The chimney has a height of 150 m and consists of the outer tubular structure of reinforced concrete and an inner chimney made of refractory brick masonry. In order to establish the possible secondary effects generated by the blasting works, a risk assessment was made with reference to seismic wave, air shock wave, noise, dust and the level of shock generated by the impact of chimney construction with the soil. The demolition work was carried out successfully and due to protection and safety measures no unwanted events were recorded, and the measured values of the seismic wave generated by the impact with the ground of the chimney were non-dangerous, being below the values estimated in the risk assessment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.