Abstract

Thermal neutron analysis (TNA) technology has been used for the non-destructive detection of explosives. The system uses a relatively weak 252Cf neutron source (1.03·107 n/s) and two 3"×3" NaI(Tl) detectors. The presence of explosives is confirmed via detection of the 10.83 MeV prompt gamma-ray associated with nitrogen decay. The MCNP4A code was used to simulate the neutron and gamma transport through the system. The thermal neutron flux in the activation position was measured using gold and indium foils. The measured thermal neutron flux was lower, by not more than 9.5%, than that of simulation. In this report the results of the preliminary tests on the system are described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.