Abstract

The study of human motor control using functional magnetic resonance imaging gives rise to many challenges. One of them is the design of haptic interfaces that are compatible with the magnetic field. To achieve this, the existing haptic interfaces employ parallel kinematics. However, they are limited to three degrees of freedom (DOFs). When trying to offer more DOF without floating actuators, parallel kinematics suffer from direct kinematic singularities, and thus, strong mechanical anisotropy. In this paper, we determine an optimal six DOF kinematics that overcomes these limitations. To this end, we use performance indices such as singularity occurrence, worst case output capabilities, sensitivity, and the global isotropy index. The resulting Octopod kinematics avoids a range of direct kinematic singularities by design. Finally, we pre-sent and evaluate a non-magnetic-resonance-compatible prototype of this novel type of kinematics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.