Abstract

The paper presents a systematic investigation of PFR - Separator - Recycle systems where exothermic and endothermic reactions are simultaneously performed. The nonlinear behaviour is analyzed, for two flowsheet alternatives and four plantwide control structures. It is shown that complex and undesired nonlinear phenomena can be avoided by providing sufficient cooling capacity or by controlling the flow rate of each reactant at reactor inlet.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.