Abstract

3 GeV RCS (rapid cycling synchrotron) at J-PARC (Japan Proton Accelerator Research Complex) comprises with several magnets of different kinds. These include seven septum magnets for the beam injection and extraction at RCS ring. Design requirements for these magnets often conflicts with efforts to minimize leakage magnetic field. Silicon steel sheets set outside of the septum magnets shield leakage magnetic fields so as to keep proper beam orbits in the ring in most cases. At the beam junction areas for beam injection and extraction, sufficient spacing is not available for installing thick magnetic shields. Vacuum chambers are made by the magnetic stainless steel to reduce the leakage field without a large shield. Results obtained from 3-D field calculations by TOSCA indicate the magnetic leakage field is suppressed down to a few Gauss or less in the present design. All septum magnets and branch structure vacuum chamber made of titanium and magnetic stainless steel are manufactured and assembled successfully. The field measurements of the septum magnets proved that both the strength and also gradient of the magnetic leakage field are diminished.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call