Abstract
This study explores the feasibility of producing electrolyzed water (EW) for post-harvest treatment of fruits and vegetables as a new substitute for current chemical products. A prototype generator using tap water and NaCl solution was tested for EW’s sanitization efficiency, energy, and economic costs. In vitro tests on Penicillium e., Aspergillus n., Botrytis c., and Alternaria a. assessed EW pH, chlorine concentration, electro-oxidative potential, pathogen contact time, and energy consumption. Optimal results were achieved with a pH of 4.6, electro-oxidative potential of 188 mV, active chlorine concentration of 3.4 mg/L, and a contact time of 1–2 min. The prototype produced 10.0 L of EW in 1 h, consuming 0.11 kWh of electricity. Real-scale energy consumption was 545 kWh/m3 EW, costing 12.51 euro/m3. The study concludes that optimizing EW production can reduce energy consumption, making it a viable alternative for industrial sanitization of fruits and vegetables.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.