Abstract
Contaminated or infected patients present a risk of cross-contamination for emergency responders, attending medical personnel and medical facilities as they enter a treatment facility. The controlled conditions of an aerosol test chamber are required to examine factors of contamination, decontamination, and cross-contamination. This study presents the design, construction, and a method for characterizing an aerosol test chamber for a full-sized manikin on a standard North Atlantic Treaty Organization litter. The methodology combined air velocity measurements, aerosol particle counts and size distributions, and computational fluid dynamics modeling to describe the chamber’s performance in three dimensions. This detailed characterization facilitates future experimental design by predicting chamber performance for a variety of patient-focused research.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.