Abstract

Abstract : The design philosophy and details of the ARL Mach 3 High Reynolds Number Facility are described and the results of extensive calibration tests are presented. The facility is an intermittent cold flow wind tunnel having a constant area test section 8 inches wide and 8.2 inches high, with a test rhombus 23 inches long. It operates in a blowdown mode using dry compressed air which is exhausted to the atmosphere through a silencer. Tunnel stagnation pressures range from 40 psia to 570 psia, with stagnation temperatures in a range from 400 degrees Rankine to 500 degrees Rankine depending upon ambient conditions. The corresponding free stream unit Reynolds numbers vary from 7 million per foot to 140 million per foot.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.