Abstract
To evaluate the safety and accuracy of use of a 3-dimensional printed navigation template in the placement of a cortical bone trajectory (CBT) screw in the middle-upper thoracic spine. Ten human cadavers were included in the study. Sixty CBT screws were placed on 1 side, using the free-hand technique, and 60 CBT screws were placed on the other side, using the navigation template that was designed and printed using data from 10 cadavers. The safety and accuracy of use of the CBT screws were directly evaluated by radiography and computed tomography. Computed tomography revealed that 2 and 3 of 60 screws, placed using the navigation template, were broken in the medial or lateral areas and in the superior or inferior pedicle wall, respectively. Furthermore, 8 screws were broken in the medial or lateral areas and 11 screws were broken in the superior or inferior pedicle wall when the free-hand technique was used. Radiography revealed that 3 screws in zone I, 55 screws in zone II, and 2 screws in zone III were placed using the navigation template. Furthermore, 7 screws in zone I, 45 screws in zone II, and 8 screws in zone III were placed using the free-hand technique. In this cadaver study, insertion of the CBT screws in the middle-upper thoracic spine with the assistance of the navigation template was safe and convenient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.