Abstract

This paper proposes a bi-stable permanent magnetic actuator (PMA) for medium voltage vacuum circuit breaker. The structure of the proposed PMA is discussed and the optimization of the structure is carried out. The model of finite element analysis (FEA) is constructed where the flux distributions, electromagnetic force under different structure parameters are analyzed. The feasibility and correctness of the PMA are verified by the FEA simulation results and the optimal size for movable plunger and stationary iron ring is obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.