Abstract
SummaryThis study presents the electromagnetic (EM) field uniformity analysis of the Korean National Radio Research Agency (RRA) reverberation chamber (RC). The analysis is performed using the normative procedure of International Electrotechnical Commission (IEC) 61000‐4‐21 for the estimation of the lowest usable frequency (LUF) of the RRA RC based on the field uniformity characterization. A full‐wave EM model of the RRA RC is designed using the method‐of‐moments (MOM) technique. The triaxial electric fields at the eight corners of the defined working volume are measured using electric field probes for the complete revolution of the mechanical stirrer. The experimental data are obtained for the frequency range of 80–1,000 MHz through the designed data acquisition software. The post‐processing of the experimental and simulation data in terms of calculation of standard deviation of recorded E‐field data, and its comparison with the defined standard deviation limit in IEC 61000‐4‐21 standard is performed to obtain the LUF of the RRA RC. A good degree of agreement was observed between the simulated and measured results of the RC field uniformity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.