Abstract

Thermoplastic composite three-stringer panels with omega stiffeners and conduction welded joints are designed, analysed and tested until final failure to investigate the performance of the welded joint in post-buckling. The three-stringer panels are designed to be structurally representative of the fuselage demonstrator of the Clean Sky 2 project STUNNING. A simplified model of the fuselage keel section is analysed by finite element analysis, using the virtual crack closure technique to model skin-stringer separation of the welded joint. The post-buckling and skin-stringer separation behaviour of the fuselage section is then adopted as the reference for the design of the three-stringer panels. Two panels are then tested. The test setup utilises digital image correlation to measure the deformation of the panels, and a high-speed camera to capture the final failure mode. The panels failed in post-buckling due to the separation of the middle stringer, with unstable separation growth followed by separation of the outer stringers and then stringer fracture. The numerical analysis of the panels, with geometrical imperfections included, is able to predict the structural behaviour accurately, with only minor differences in buckling shape and separation behaviour.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call