Abstract

This study presents a design method for the continuous switching test circuits of power devices. Depending on the relationship between the rated voltage of a DC voltage source and device under test (DUT), two types of test circuits are proposed. These test circuits comprise a cascaded buck-boost (or boost-buck) converter to achieve power regeneration. Based on analysis of the test circuits, a design method is proposed to ensure that any failure does not spread to the test circuit even when the DUT fails during the continuous switching tests. A test circuit is designed according to the proposed method, and its experimental results demonstrate the validity of the proposed design.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.