Abstract

This paper presents an active Fault Tolerant Control (FTC) strategy for induction motor (IM) that ensures Field Oriented Control (FOC) and offset the effect of the sensor faults despite of the load torque disturbance. The proposed approach uses a fuzzy descriptor approach to estimate simultaneously the system state and the sensor fault. The physical model of IM is approximated by the Takagi-Sugeno (T-S) fuzzy technique in the synchronous d-q rotating frame with field-oriented control strategy. The stability conditions are analyzed using Lyapunov theory. The controller and observers gains are calculated by solving a set of Linear Matrix Inequalities (LMIs). Finally, the effectiveness of the proposed strategy have been illustrated in simulation and experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.