Abstract
Purposes : To assess the degree of overestimation in low-dose cancer risk when models linear in dose are fitted to cancer data. Materials and methods : Examination of the quadratic and the linear coefficients (in dose) in the Japanese atomic bomb survivor cancer incidence data, based on follow-up to 1987 and taking separate account of random errors in DS86 neutron and DS86 gamma dose estimates and systematic errors in Hiroshima DS86 neutron dose estimates. Results : When the 0-4 Gy dose range is used, the low-dose extrapolation factor for all solid tumours, assessing the degree to which low-dose cancer risks are overestimated by fitting a model linear in dose, is 1.06 (95% CI 0.78, 1.62) and so is not significantly different from 1; the associated ratio of the quadratic to the linear coefficients is 0.06 Sv -1 (95% CI - 0.22, 0.67). The best estimate of the low-dose extrapolation factor for leukaemia is 2.47 (95% CI 1.24, > 1000). The ratio of the quadratic to the linear coefficients is 1.81 Sv -1 (95% CI 0.21, > 1000). When various types and groupings of solid tumours are considered there is not generally any strong evidence for upward curvature; for only two out of the six solid tumour groupings are there indications of appreciable upward curvature in the dose response, and in no instance is this statistically significant. Consideration of a lower dose range (0-2 Gy rather than 0-4 Gy) results in the low-dose extrapolation factor for solid tumours increasing to 1.21 (95% CI 0.81, 2.45), with corresponding increases for solid tumour subtypes; the corresponding quantity for leukaemia decreases to 1.73 (95% CI 0.79, 147.67). Three out of the six solid tumour subtypes now show appreciable upward curvature. If there is additional adjustment of the Hiroshima neutron dose estimates over the 0-2 Gy dose range, the low-dose extrapolation factor for all solid tumours increases still further, to 1.43 (95% CI 0.97, 2.72), whereas for leukaemia this quantity is further reduced, to 1.58 (95% CI 0.90, 10.58). Conclusions : There is marked upward curvature in the dose response for leukaemia. For solid tumours there is little indication of upward curvature in the dose response over the 0-4 Gy dose range, although over the 0-2 Gy dose range and after adjustment of Hiroshima DS86 neutron dose estimates the upward curvature is more pronounced. Uncertainties in the likely adjustments to the Hiroshima DS86 neutron dose estimates imply that these findings should be treated with caution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.