Abstract

This study determined the hardness and curing depth of a light-activated indirect composite polymerized with three laboratory light-polymerizing units for the purpose of comparing the curing performance of the three units. A light-activated composite material for indirect application (Vita Zeta) was polymerized with three light-polymerizing units equipped with the following light sources: 1) one halogen lamp and two fluorescent lamps (alpha-Light II); 2) three halogen lamps (Twinkle HLG); and 3) one metal halide lamp (Twinkle LI). Knoop hardness and curing depth were determined for groups of five specimens using standardized testing methods. The results were compared using analysis of variance (ANOVA) and Scheffé's S intervals (alpha = 0.05). The Knoop hardness number (KHN) generated with the halogen-fluorescent unit (12.5 KHN) was significantly (P < 0.05) lower than those produced by the halogen unit (13.9 KHN) and the metal halide unit (14.2 KHN). Of the three units, the halogen-fluorescent unit exhibited the lowest depth of cure. Both the hardness and curing depth of the composite were influenced by the laboratory polymerizing units employed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.