Abstract
With homemade active crystalline fibers, we generated bright and broadband light sources for full-field optical coherence tomography, offering deep penetration into skin tissues with cellular resolution at a high frame rate. Extraction of backscattered spectra from the tissue has potential applications in biomedicine. The hysteresis nonlinearity of the piezoelectric transducer actuating the Mirau interferometer has been greatly reduced by a feedforward compensation approach. The linearized hysteresis response enables us to extract depth-dependent spectra accurately. To validate, the complex dispersion of a fused silica plate was characterized with 2% error. Further validation on an in vitro setting, the backscattered spectra from indocyanine green pigment and nonpigmented microspheres were obtained and verified. For in vivo skin measurement, the backscattered spectra show depth-dependent spectral shift and bandwidth variation due to the complex skin anatomy and pigment absorption. Such a high-speed spectra acquisition of in vivo deep tissue backscattering could lead to disease diagnosis in clinical settings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.