Abstract

In this paper deposition rate coefficients for unattached and attached radon progeny were estimated according to a particle deposition model for turbulent indoor airflow described by Zhao and Wu [2006. Modeling particle deposition from fully developed turbulent flow in ventilation duct. Atmos. Environ. 40, 457–466]. The parameter which characterizes turbulent indoor airflow in this model is friction velocity, u*. Indoor ventilation changes indoor airflow and friction velocity and influences deposition rate coefficients. Correlation between deposition and ventilation rate coefficients in the room was determined. It was shown that deposition rate coefficient increases with ventilation rate coefficient and that these parameters of the Jacobi room model cannot be assumed to be independent. The values of deposition rate coefficients were presented as functions of friction velocity and ventilation rate coefficient. If ventilation rate coefficient varies from 0.1 up to 1 h −1, deposition rate coefficients for unattached and attached fractions were estimated to be in the range 3–110 h −1 and 0.015–0.35 h −1, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.