Abstract
AbstractBulk metallic glass demonstrates superior mechanical properties and excellent bio‐mechanical stability compared to routinely used biomaterials like titanium, cobalt‐chromium, stainless steel, et cetera. However, the metallic glass surface do not easily adhere to the leaving tissues due to native bio‐inert oxide layer, which have poor wear resistance and low hardness. In this current study an innovative method for surface coating of bulk metallic glass by mixing hydroxyapatite powder during electro‐discharge machining has been employed. A biomimetic nano‐porous bio‐ceramic layer of oxides and carbides was deposited on metallic glass surface. The modified surface integrity and composition were investigated by scanning electron microscopy, energy‐dispersive x‐ray spectroscopy, and x‐ray diffraction characterization techniques. The characterization results confirmed the formation of a natural bone‐like nano‐porous surface topography on the metallic glass surface using a novel hydroxyapatite‐mixed electro‐discharge coating process. In addition, a favourable surface chemistry in the form of bioceramic carbides (zirconium carbide, titanium carbide) and zirconium oxide layers, was achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.